Switch Fabric |
● Full digital, non-blocking
|
|
Electrical
Specifications |
● 45 watts (154 BTUs/hr.) per PARTNER®
Advanced Communications System processor
module during normal power consumption
● 85 watts (290 BTUs/hr.) per PARTNER®
Advanced Communications System processor
module during maximum power consumption
● 10 watts (35 BTUs/hr.) per 400 module, normal
and maximum power consumption
● 42 watts (147 BTUs/hr.) per 308 module, normal
and maximum power consumption
● 16 watts (56 BTUs/hr.) per 1600 DSL module,
normal and maximum power consumption
● 45 days to 6 months memory backup with 2
AAA-size standard alkaline batteries (IEC LR03)
|
Processor Module
Specifications |
● 68306 16 Mhz processor
● 256 Kbyte RAM
● 512 Kbyte Flash ROM
● Custom VLSI DSP ASIC16-bit, 52 MHz
|
Extension Jack
Specifications |
● Ringing voltage: +5 VDC, -140 VDC peak to
peak; trapezoidal wave shaping
● 35 to 38 Volt talk battery
● Ringing frequency: 20 Hz
|
Page Jack
Specifications |
● Accepts 2 Volts at 50 Kohms maximum input
● 0-18 dB attenuation
|
Contact Closure
Adjunct Jack Specifications |
● Operates up to 150 feet (45.72 meters) from
control unit using 24 gauge solid conductor wire
if 2 contact closure devices are used; up to 800
feet (243.84 meters) from control unit using 24
gauge solid conductor wire if 1 contact closure
device is used
● Install the contact closure adjunct in the same
building as the control unit; cannot be installed
out-of-doors
● Has 3 terminals per contact closure, providing a
normally open and normally closed function for
each contact closure
● Maximum contact voltages and current
● 30 VAC, 1 Amp
● 50 VDC, 1 Amp
|
SMDR Output Format |
● 1200 baud
● 8 data bits
● XON/XOFF protocol
● Line feeds
● No parity
● 2 stop bits
● Carriage return
|
Environmental
Requirements: Control Units |
● Mount on a wall at least 2 feet (0.6 meters)
from the floor (wall mounting required)
● Locate within 5 feet (1.5 meters) of the network
interface jacks and a properly grounded electrical
outlet not controlled by a switch, using supplied
7-foot (2.1 meter) cords
● Operating temperature of room: 32 to +104 F
(0 to +40 C), not in direct sunlight
● Humidity 15% to 90% non-condensing
● For proper ventilation and easy replacement of
modules, provide the following maximum clearance
around the control units:
● 5-slot carrier: 1 foot (0.3 meter) clearance at the
top and sides, and 2 feet (0.6 meter) clearance at
the front and bottom
● 2-slot carrier or stand-alone PARTNER® Advanced
Communications System processor module:
1 foot (0.3 meter) clearance at the front, top,
and right side, and 2 feet (0.6 meter) clearance
at the bottom and left side
● Locate in an area free of excess moisture, corrosive
gases, dust, and chemicals
|
Electrical
Requirements: Control Units |
● U.S. and Canada: 90-130 VAC, 50-60 Hz,
3-prong outlet separate ground, separately
fused at 15 Amps
● Other countries: 90-264 VAC
(220 VAC fused at 10 Amps)
● Grounding to comply with Underwriters
Laboratories (UL) 1459
|
Requirements for
Out-of-the Building Installations |
● Installation of a telephone or other standard
(tip/ring) device in another building requires
the following In-Range-Out-of-Building (IROB)
protectors to protect the control unit and device
from electrical surges:
● System phone: 2 IROB protectors
● Standard phone: 1 IROB protector plus
1 carbon block protector
● Installation of a contact closure adjunct controlled
device outside the building requires a surge protector
to protect the control unit from electrical surges.
|
Wiring |
System phones: At least 2-pair (4-wire) star ("home run" not "loop") Other standard telecommunications equipment: 1-pair (2 wire) mounting cords Bridging adapter: 267F2 Range: 1000 feet (305 meters) for system phones; 3,000 feet (915 meters) for standard devices
|
|
Safety
Requirements |
● U.S.: Meets UL 1459 Issue 2
● Canada: Meets CSA C22.2.225
● All other countries: Meets IEC950 Second
Edition and EN60950 Second Edition
|
U.S. |
● FCC Part 68 approval
● FCC registration number (U.S.) See the label
on the side of the control unit
● PCC Part 15 approval
● Class A: 5-slot configuration; 2-slot
configuration with PARTNER® Messaging
● Class B: PARTNER® Advanced Communications
System stand-alone configuration; 2-slot
configuration with 308EC, 400EC, and PARTNER®
Advanced Communications System processor
modules
● REN (outside line jack): 0.9A per line jack
● Jack type: RJ11C
● Loop start lines
|
Canada |
● IC CP01, Issue 7
● IC registration number (Canada): See the
label on the side of the control unit
● IC CS03, Issues 6 & 7
● Load Number = 7
● Loop start lines
|
Other |
● For all other countries, please contact relevant
jurisdiction authorities
|