Switch Fabric | 
              
              
                | ● Full digital, non-blocking
                 | 
              
              
                |   | 
              
              
                | 
                Electrical 
                Specifications | 
              
              
                
                
                  ● 45 watts (154 BTUs/hr.) per PARTNER® 
                   
  Advanced Communications System processor  
  module during normal power consumption  
                  ● 85 watts (290 BTUs/hr.) per PARTNER® 
                   
  Advanced Communications System processor  
  module during maximum power consumption  
                  ● 10 watts (35 BTUs/hr.) per 400 module, normal 
                   
  and maximum power consumption  
                  ● 42 watts (147 BTUs/hr.) per 308 module, normal 
                   
  and maximum power consumption  
                  ● 16 watts (56 BTUs/hr.) per 1600 DSL module, 
                   
  normal and maximum power consumption  
                  ● 45 days to 6 months memory backup with 2 
                   
  AAA-size standard alkaline batteries (IEC LR03)  
                 
                 | 
              
              
                | 
                Processor Module 
                Specifications | 
              
              
                
                
                  ● 68306 16 Mhz processor
                   
                  ● 256 Kbyte RAM  
                  ● 512 Kbyte Flash ROM  
                  ● Custom VLSI DSP ASIC16-bit, 52 MHz  
                 
                 | 
              
              
                | 
                Extension Jack 
                Specifications | 
              
              
                
                
                  ● Ringing voltage: +5 VDC, -140 VDC peak to 
                   
  peak; trapezoidal wave shaping  
                  ● 35 to 38 Volt talk battery  
                  ● Ringing frequency: 20 Hz  
                 
                 | 
              
              
                | 
                Page Jack 
                Specifications | 
              
              
                
                
                  ● Accepts 2 Volts at 50 Kohms maximum input
                   
                  ● 0-18 dB attenuation 
                 
                 | 
              
              
                | 
                Contact Closure 
                Adjunct Jack Specifications | 
              
              
                
                
                  ● Operates up to 150 feet (45.72 meters) from 
                   
  control unit using 24 gauge solid conductor wire  
  if 2 contact closure devices are used; up to 800  
  feet (243.84 meters) from control unit using 24  
  gauge solid conductor wire if 1 contact closure  
  device is used  
                  ● Install the contact closure adjunct in the same  
  building as the control unit; cannot be installed  
  out-of-doors  
                  ● Has 3 terminals per contact closure, providing a  
  normally open and normally closed function for  
  each contact closure  
                  ● Maximum contact voltages and current  
     ● 30 VAC, 1 Amp  
     ● 50 VDC, 1 Amp  
                 
                 | 
              
              
                | 
                SMDR Output Format | 
              
              
                
                
                  ● 1200 baud  
                  ● 8 data bits  
                  ● XON/XOFF protocol  
                  ● Line feeds  
                  ● No parity  
                  ● 2 stop bits  
                  ● Carriage return  
                 
                 | 
              
              
                | 
                Environmental 
                Requirements: Control Units | 
              
              
                
                
                  ● Mount on a wall at least 2 feet (0.6 meters) 
                   
  from the floor (wall mounting required)  
                  ● Locate within 5 feet (1.5 meters) of the network  
  interface jacks and a properly grounded electrical  
  outlet not controlled by a switch, using supplied  
  7-foot (2.1 meter) cords  
                  ● Operating temperature of room: 32 to +104 F  
  (0 to +40 C), not in direct sunlight  
                  ● Humidity 15% to 90% non-condensing  
                  ● For proper ventilation and easy replacement of  
  modules, provide the following maximum clearance  
  around the control units:  
     ● 5-slot carrier: 1 foot (0.3 meter) clearance at the 
                   
       top and sides, and 2 feet (0.6 meter) clearance at 
                   
       the front and bottom  
     ● 2-slot carrier or stand-alone PARTNER® Advanced 
                   
       Communications System processor module:  
       1 foot (0.3 meter) clearance at the front, top, 
                   
       and right side, and 2 feet (0.6 meter) clearance 
                   
       at the bottom and left side  
                  ● Locate in an area free of excess moisture, corrosive  
   gases, dust, and chemicals  
                 
                 | 
              
              
                | 
                Electrical 
                Requirements: Control Units | 
              
              
                
                
                  ● U.S. and Canada: 90-130 VAC, 50-60 Hz, 
                   
  3-prong outlet separate ground, separately  
  fused at 15 Amps  
                  ● Other countries: 90-264 VAC  
  (220 VAC fused at 10 Amps)  
                  ● Grounding to comply with Underwriters  
  Laboratories (UL) 1459 
                 
                 | 
              
              
                | 
                Requirements for 
                Out-of-the Building Installations | 
              
              
                
                
                  ● Installation of a telephone or other standard 
                   
  (tip/ring) device in another building requires  
  the following In-Range-Out-of-Building (IROB)  
  protectors to protect the control unit and device  
  from electrical surges:  
   ● System phone: 2 IROB protectors  
   ● Standard phone: 1 IROB protector plus  
     1 carbon block protector  
                  ● Installation of a contact closure adjunct controlled  
  device outside the building requires a surge protector  
  to protect the control unit from electrical surges.  
                 
                 | 
              
              
                | 
                Wiring | 
              
              
                | System phones: At least 2-pair (4-wire) star ("home run" not "loop") Other standard telecommunications equipment: 1-pair (2 wire) mounting cords Bridging adapter: 267F2 Range: 1000 feet (305 meters) for system phones; 3,000 feet (915 meters) for standard devices
                 | 
              
              
                |   | 
              
              
                | 
                Safety 
                Requirements | 
              
              
                
                
                  ● U.S.: Meets UL 1459 Issue 2
                   
                  ● Canada: Meets CSA C22.2.225  
                  ● All other countries: Meets IEC950 Second  
  Edition and EN60950 Second Edition  
                 
                 | 
              
              
                | 
                U.S. | 
              
              
                
                
                  ● FCC Part 68 approval  
                  ● FCC registration number (U.S.) See the label  
  on the side of the control unit  
                  ● PCC Part 15 approval  
     ● Class A: 5-slot configuration; 2-slot  
        configuration with PARTNER® Messaging
                   
     ● Class B: PARTNER® Advanced Communications  
        System stand-alone configuration; 2-slot 
                   
        configuration with 308EC, 400EC, and PARTNER® 
                   
        Advanced Communications System processor 
                   
        modules  
                  ● REN (outside line jack): 0.9A per line jack  
                  ● Jack type: RJ11C  
                  ● Loop start lines  
                 
                 | 
              
              
                | 
                 Canada | 
              
              
                
                
                  ● IC CP01, Issue 7  
                  ● IC registration number (Canada): See the  
   label on the side of the control unit  
                  ● IC CS03, Issues 6 & 7  
                  ● Load Number = 7  
                  ● Loop start lines  
                 
                 | 
              
              
                | 
                Other | 
              
              
                
                
                  ● For all other countries, please contact relevant 
                   
  jurisdiction authorities  
                 
                 |